Show simple item record

FieldValueLanguage
dc.contributor.authorPicone, Dean
dc.contributor.authorCôté, Nadège
dc.contributor.authorCorney, Raphaela
dc.contributor.authorSharman, James E.
dc.contributor.authorAgharazii, Mohsen
dc.contributor.authorGoupil, Rémi
dc.date.accessioned2024-07-17T22:24:30Z
dc.date.available2024-07-17T22:24:30Z
dc.date.issued2024en_AU
dc.identifier.urihttps://hdl.handle.net/2123/32812
dc.description.abstractObjectives. Central aortic BP may predict cardiovascular outcomes better than upper-arm brachial BP. In recent years technology has enabled central BP estimation by recording a peripheral BP waveform from a standard upper-arm cuff. The accuracy of these devices is not well documented, and this study aimed to address this issue. Methods. This study was a systematic review, conducted according to PRISMA guidelines, of observational studies published between 2008-2023 that reported accuracy testing of cuff-based central BP devices, compared to reference invasive aortic BP. The primary analysis was stratified according to each commercially available device. Pooled estimates were calculated using random-effects models based on mean differences and standard errors. Results. 6,415 studies were screened, and 27 studies met inclusion criteria (plus one unpublished study). This generated data for seven devices that are commercially available, which were tested among 2,125 adult participants. There was very high heterogeneity when all devices were pooled (I2=97.5%), and, when stratified by device, the accuracy of estimated central BP was highly device dependent (range of accuracy across different devices -12.4 mmHg (-16.3 to -8.5) to 3.2 mmHg (0.2 to 6.1)). Two of the seven commercially available devices had not undergone external validation testing. Conclusions. The accuracy of commercially available cuff-based central BP devices is highly device-specific and not all are accurate for the estimation of central SBP. These findings have major implications for the appropriate interpretation of studies that use cuff-based estimated central BP.en_AU
dc.publisherWoltersen_AU
dc.relation.ispartofJournal of Hypertensionen_AU
dc.subjectpulse wave analysisen_AU
dc.subjectblood pressure determinationen_AU
dc.subjectvascular stiffnessen_AU
dc.subjectcardiovascular diseasesen_AU
dc.titleAccuracy of methods to estimate central aortic systolic blood pressure via upper-arm cuff: a systematic review and meta-analysisen_AU
dc.typeArticleen_AU
dc.subject.asrcANZSRC FoR code::42 HEALTH SCIENCESen_AU
dc.identifier.doi10.1097/HJH.0000000000003770
dc.type.pubtypeAuthor accepted manuscripten_AU
dc.relation.nhmrcGNT2018077
dc.rights.otherThis is a pre-copyedited, author-produced version of an article accepted for publication in Journal of Hypertension. The published version of record Picone, Dean S.a,b; Côté, Nadègec; Corney, Raphaelab; Sharman, James E.b; Agharazii, Mohsenc; Goupil, Rémid. Accuracy of methods to estimate central aortic SBP via upper arm cuff: a systematic review and meta-analysis. Journal of Hypertension ():10.1097/HJH.0000000000003770, May 14, 2024. | DOI: 10.1097/HJH.0000000000003770 is available online at: https://doi.org/10.1097/hjh.0000000000003770.en_AU
usyd.facultySeS faculties schools::Faculty of Medicine and Health::School of Health Sciencesen_AU
workflow.metadata.onlyNoen_AU


Show simple item record

Associated file/s

Associated collections

Show simple item record

There are no previous versions of the item available.