Show simple item record

FieldValueLanguage
dc.contributor.authorKeall, Paul
dc.contributor.authorNguyen, Doan
dc.contributor.authorO'Brien, Ricky
dc.contributor.authorHewson, Emily
dc.contributor.authorBall, Helen
dc.contributor.authorBooth, Jeremy
dc.contributor.authorGreer, Peter
dc.contributor.authorMoodie, Trevor
dc.contributor.authorHardcastle, Nick
dc.contributor.authorPoulsen, Per
dc.contributor.authorArumugam, Sankar
dc.contributor.authorMartin, Jarad
dc.contributor.authorKneebone, Andrew
dc.contributor.authorSiva, Shankar
dc.contributor.authorTai, Keen-Hun
dc.contributor.authorTurner, Sandra
dc.contributor.authorEade, Thomas
dc.contributor.authorHayden, Amy
dc.contributor.authorSidhom, Mark
dc.contributor.authorHruby, George
dc.contributor.authorHunter, Perry
dc.contributor.authorWilton, Lee
dc.contributor.authorBromley, Regina
dc.contributor.authorKipritidis, John
dc.contributor.authorGebski, Val
dc.contributor.authorLi, Yifan
dc.contributor.authorSengupta, Chandrima
dc.coverage.spatialAustraliaen_AU
dc.coverage.temporal2016-2020en_AU
dc.date.accessioned2023-04-12T03:52:44Z
dc.date.available2023-04-12T03:52:44Z
dc.date.issued2023-04-12
dc.identifier.urihttps://hdl.handle.net/2123/31090
dc.description.abstractThe data originate from the Trans-Tasman Radiation Oncology Group (TROG) 15.01 Stereotactic Prostate Adaptive Radiotherapy utilizing Kilovoltage intrafraction monitoring (SPARK) clinical trial. The SPARK trial was a phase II prospective multi-institutional clinical trial approved by the Hunter New England Local Health District Human Research Ethics Committee, (HREC/15/HNE/216) and registered with clinicaltrials.gov (NCT02397317). The aim of the SPARK clinical trial was to measure the geometric and dosimetric cancer targeting accuracy achieved with a real-time image-guided radiotherapy technology named Kilovoltage Intrafraction Monitoring (KIM) for 48 prostate cancer patients treated in 5 treatment sessions. The clinical trial was performed at 5 radiotherapy centers situated in New South Wales and Victoria in Australia. During treatment, real-time tumor translational and rotational motion were determined from x-ray images using the KIM technology. Two methods were allowed to adapt to tumor motion during treatment: (1) gating by applying KIM-triggered couch shifts and (2) multi-leaf (MLC) tracking. A dose reconstruction method was used to evaluate the dose delivered to the target and organs-at-risk with and without real-time KIM monitoring. Patient reported outcomes and toxicity data were monitored up to 2 years after the completion of the treatment. The dataset contains 48 prostate cancer patient data including the planning CT images, treatment plans, RT structure sets, planned and motion-included dose volume histograms, intra-treatment kilovoltage (kV) and megavoltage (MV) projection images, tumor translational and rotational motion determined by KIM, tumor motion ground truth data determined by the triangulation method, the linear accelerator trajectory traces and patient treatment outcomes.en_US
dc.language.isoenen_AU
dc.rightsCreative Commons Attribution 4.0en_AU
dc.subjectIntra-fraction motion managementen_AU
dc.subjectProstate SABRen_AU
dc.subjectProstate radiotherapyen_AU
dc.subjectMotion included doseen_AU
dc.subjectProstate SABR treatment outcomesen_AU
dc.subjectKilovoltage Intrafraction Monitoringen_AU
dc.subjectIntra-fraction prostate kilovoltage and megavoltage imagesen_AU
dc.subjectTumor trackingen_US
dc.titleTROG 15.01 Stereotactic Prostate Adaptive Radiotherapy utilizing Kilovoltage Intrafraction Monitoring (SPARK) Databaseen_US
dc.typeDataseten_AU
dc.subject.asrc510502en_AU
dc.identifier.doi10.25910/qg5d-6058
dc.description.methodThe data originate from the Trans-Tasman Radiation Oncology Group (TROG) 15.01 Stereotactic Prostate Adaptive Radiotherapy utilising Kilovoltage intrafraction monitoring (SPARK) clinical trial. In the SPARK clinical trial, 48 prostate cancer patients received 36.25 Gy dose (planning target volume D95) in 5 fractions of stereotactic body radiation therapy (SBRT) using Volumetric Modulated Arc Therapy over two arcs with treatment delivered on Varian TrueBeam, Varian Trilogy and Elekta linear accelerators at 5 radiotherapy centers in Australia. Fiducial markers were inserted into the prostate prior to treatment planning. During radiation therapy, real-time tumour translational and rotational motion were determined from x-ray images using the Kilovoltage Intrafraction Monitoring (KIM) technology. Two methods were allowed to adapt to tumour motion during treatment: gating by applying KIM-triggered couch shifts and multi-leaf (MLC) tracking. A dose reconstruction method was used to evaluate the dose delivered to the target and organs-at-risk with and without real-time KIM monitoring. Patient reported outcomes and toxicity data were monitored up to 2 years after the completion of the treatment. More details on the data structure can be found in the README file within the repository. The data anonymisation and analysis codes are available on the public Image X GitHub repository: github.com/ACRF-Image-X-Institute/SPARK-data-analysis-code.en_AU
dc.bitstream.urlhttps://ses-data.library.sydney.edu.au/public/31090_Keall/Center1.7z
dc.bitstream.urlhttps://ses-data.library.sydney.edu.au/public/31090_Keall/Center2_IntrafractionImages_Patient01-04.7z
dc.bitstream.urlhttps://ses-data.library.sydney.edu.au/public/31090_Keall/Center2_IntrafractionImages_Patient05-08.7z
dc.bitstream.urlhttps://ses-data.library.sydney.edu.au/public/31090_Keall/Center2_IntrafractionImages_Patient09-12.7z
dc.bitstream.urlhttps://ses-data.library.sydney.edu.au/public/31090_Keall/Center2_IntrafractionImages_Patient13-16.7z
dc.bitstream.urlhttps://ses-data.library.sydney.edu.au/public/31090_Keall/Center2_IntrafractionImages_Patient17-20.7z
dc.bitstream.urlhttps://ses-data.library.sydney.edu.au/public/31090_Keall/Center2_AllOtherData.7z
dc.bitstream.urlhttps://ses-data.library.sydney.edu.au/public/31090_Keall/Center3_IntrafractionImages_Patient01-03.7z
dc.bitstream.urlhttps://ses-data.library.sydney.edu.au/public/31090_Keall/Center3_IntrafractionImages_Patient04-05.7z
dc.bitstream.urlhttps://ses-data.library.sydney.edu.au/public/31090_Keall/Center3_AllOtherData.7z
dc.bitstream.urlhttps://ses-data.library.sydney.edu.au/public/31090_Keall/Center4.7z
dc.bitstream.urlhttps://ses-data.library.sydney.edu.au/public/31090_Keall/Center5.7z
dc.relation.otherCancer Australia (APP1081534)
dc.relation.otherProstate Cancer Foundation of Australia
dc.relation.otherCancer Australia (APP1085360)
usyd.facultySeS faculties schools::Faculty of Medicine and Healthen_AU
usyd.departmentImage X Institute, The University of Sydneyen_AU
workflow.metadata.onlyYesen_AU


Show simple item record

Associated file/s

Associated collections

Show simple item record