Show simple item record

FieldValueLanguage
dc.contributor.authorEslick, EM
dc.contributor.authorKipritidis, J
dc.contributor.authorGradinscak, D
dc.contributor.authorStevens, MJ
dc.contributor.authorBailey, DL
dc.contributor.authorHarris, B
dc.contributor.authorBooth, JT
dc.contributor.authorKeall, P
dc.date.accessioned2019-06-25
dc.date.available2019-06-25
dc.date.issued2018-05-01
dc.identifier.citationRadiother Oncol. 2018 May;127(2):267-273.en_AU
dc.identifier.urihttp://hdl.handle.net/2123/20629
dc.description.abstractBACKGROUND AND PURPOSE: CT ventilation imaging (CTVI) derived from four dimensional CT (4DCT) has shown only moderate spatial accuracy in humans due to 4DCT image artefacts. Here we assess the accuracy of an improved CTVI using high quality exhale/inhale breath-hold CT (BHCT). MATERIALS AND METHODS: Eighteen lung cancer patients underwent exhale/inhale BHCT, 4DCT and Galligas PET ventilation scans in a single imaging session. For each BHCT and 4DCT scan, we performed deformable image registration (DIR) between the inhale and exhale phase images to quantify ventilation using three published metrics: (i) breathing induced lung density change, CTVIDIR-HU (ii) breathing induced volume change CTVIDIR-Jac and (iii) the regional air-tissue product, CTVIHU Spatial accuracy was reported as the voxel-wise Spearman correlation r between CTVI and Galligas PET. RESULTS: For BHCT-based CTVIs (N = 16), the CTVIDIR-HU, CTVIDIR-Jac and CTVIHU methods yielded mean (range) r values of 0.67 (0.52-0.87), 0.57 (0.18-0.77) and 0.49 (0.14-0.75) respectively. By comparison the 4DCT-based CTVIs (n = 14) had values of 0.32 (-0.04 to 0.51), 0.16 (-0.31 to 44) and 0.49 (0.20-0.77) respectively. CONCLUSIONS: High quality CT imaging is a key requirement for accurate CT ventilation imaging. The use of exhale/inhale BHCT can improve the accuracy of CTVI for human subjects.en_AU
dc.publisherElsevieren_AU
dc.relationNHMRC 1112096en_AU
dc.rights©2018. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/en_AU
dc.subjectLung canceren_AU
dc.subjectCt ventilation imagingen_AU
dc.titleCT ventilation imaging derived from breath hold CT exhibits good regional accuracy with Galligas PET.en_AU
dc.typeArticleen_AU
dc.subject.asrcFoR::029903 - Medical Physicsen_AU
dc.identifier.doi10.1016/j.radonc.2017.12.010
dc.type.pubtypePost-printen_AU


Show simple item record

Associated file/s

Associated collections

Show simple item record

There are no previous versions of the item available.