Show simple item record

FieldValueLanguage
dc.contributor.authorCastellino, Brendan
dc.contributor.authorWills, Daniel
dc.contributor.authorTan, Christopher
dc.contributor.authorlloyd, Max
dc.contributor.authorWalsh, William
dc.date.accessioned2026-02-25T03:06:49Z
dc.date.available2026-02-25T03:06:49Z
dc.date.issued2026-02-25
dc.identifier.urihttps://hdl.handle.net/2123/34893
dc.description.abstractArticular fractures require precise anatomical reduction and rigid fixation to heal appropriately. In veterinary cases that involve fracturing of the lateral humeral condyle, cortical bone screws inserted in lag fashion with Kirschner wire are the preferred method for surgical fixation. However, relatively high complication rates associated with cortical lag screws (CLSs) highlights the need to investigate alternate screw designs. Variable-pitch headless compression screws (VPHCSs) are unique as they advance beneath the cortical surface. Although the use of VPHCSs are widely utilised in human orthopaedics, the current use in veterinary orthopaedics is limited. This study aimed to evaluate the peak interfragmentary force (PIF) and area of compression (AOC) generated by a 3.5 mm self-tapping cortical screw placed in lag fashion and a 3.5 mm VPHCS inserted to four depths. PIF and AOC were measured using a pressure-sensitive film placed between two blocks of polyurethane foam (0.24 g/cm3), simulating a transverse fracture. CLS were inserted by hand into predrilled 2.5 mm pilot holes. PIF and AOC were measured at full insertion. VPHCSs were placed into predrilled 2.5 mm pilot holes, followed by a 3.5 mm tapered countersink. The screw was inserted until the head was level with the surface. PIF and AOC were measured between the two blocks. The screw was continued until the head was at a depth of 2, 5, and 9 mm below the surface, and the PIF and AOC were measured again at each stage. There was no detectable difference in PIF and AOC between CLSs and VPHCSs countersunk to −2 mm (PIF–CLS: Mean= 12.886, SD= 2.370; 2 mm: Mean= 17.301, SD= 8.858, p = 0.319; AOC–CLS: Mean= 0.936, SD= 0.291; 2 mm: Mean= 0.925, SD= 0.447, p = 0.872). VPHCSs countersunk to −5 mm and −9 mm produced significantly greater PIF compared to CLSs (5 mm: Mean= 16.086, SD= 6.799, p = 0.002; 9 mm: Mean= 34.987, SD= 4.015, p < 0.001). VPHCSs countersunk to −5 and −9 mm produced significantly greater PIF and AOC compared to CLSs in this model. Further investigation is required to produce recommendations for clinical use.en
dc.language.isoenen
dc.rightsCreative Commons Attribution 4.0en
dc.subjectheadless compression screwsen
dc.subjectcortical lag screwsen
dc.subjectinterfragmentary compressionen
dc.subjectfracture repairen
dc.subjectarea of compressionen
dc.titleThe Effect of Variable-Pitch Headless Compression Screws and Cortical Screws on Interfragmentary Compression: An In-Vitro Polyurethane Foam Block Modelen
dc.typePreprinten
dc.identifier.doi10.25910/z1m3-3281
usyd.facultySeS faculties schools::Faculty of Science::University of Sydney School of Veterinary Scienceen
workflow.metadata.onlyYesen


Show simple item record

Associated file/s

Associated collections

Show simple item record

There are no previous versions of the item available.