dc.description.abstractPurpose: In multileaf collimator (MLC) tracking, the MLC positions from the original treatment plan are continuously modified to account for intrafraction tumor motion. As the treatment is adapted in real time, there is additional risk of delivery errors which cannot be detected using traditional pretreatment dose verification. The purpose of this work is to develop a system for real-time geometric verification of MLC tracking treatments using an electronic portal imaging device (EPID). Methods: MLC tracking was utilized during volumetric modulated arc therapy (VMAT). During these deliveries, treatment beam images were taken at 9.57 frames per second using an EPID and frame grabber computer. MLC positions were extracted from each image frame and used to assess delivery accuracy using three geometric measures: the location, size, and shape of the radiation field. The EPID-measured field location was compared to the tumor motion measured by implanted electromagnetic markers. The size and shape of the beam were compared to the size and shape from the original treatment plan, respectively. This technique was validated by simulating errors in phantom test deliveries and by comparison between EPID measurements and treatment log files. The method was applied offline to images acquired during the LIGHT Stereotactic Ablative Body Radiotherapy (SABR) clinical trial, where MLC tracking was performed for 17 lung cancer patients. The EPID-based verification results were subsequently compared to post-treatment dose reconstruction. Results: Simulated field location errors were detected during phantom validation tests with an uncertainty of 0.28 mm (parallel to MLC motion) and 0.38 mm (perpendicular), expressed as a root-mean-square error (RMSError ). For simulated field size errors, the RMSError was 0.47 cm2 and field shape changes were detected for random errors with standard deviation ≥ 2.5 mm. For clinical lung SABR deliveries, field location errors of 1.6 mm (parallel MLC motion) and 4.9 mm (perpendicular) were measured (expressed as a full-width-half-maximum). The mean and standard deviation of the errors in field size and shape were 0.0 ± 0.3 cm2 and 0.3 ± 0.1 (expressed as a translation-invariant normalized RMS). No correlation was observed between geometric errors during each treatment fraction and dosimetric errors in the reconstructed dose to the target volume for this cohort of patients. Conclusion: A system for real-time delivery verification has been developed for MLC tracking using time-resolved EPID imaging. The technique has been tested offline in phantom-based deliveries and clinical patient deliveries and was used to independently verify the geometric accuracy of the MLC during MLC tracking radiotherapy.en
dc.language.isoenen
dc.publisherWileyen
dc.relation.ispartofMedical Physicsen
dc.rightsOtheren
dc.subjectEPIDen
dc.subjectMLC trackingen
dc.subjectreal timeen
dc.subjectverificationen
dc.titleToward real-time verification for MLC tracking treatments using time-resolved EPID imaging.en
dc.typeArticleen
dc.subject.asrc0299 Other Physical Sciencesen
dc.identifier.doi10.1002/mp.14675
dc.type.pubtypeAuthor accepted manuscripten
dc.relation.nhmrc1112096
dc.rights.otherThis is the peer reviewed version of the following article: Toward real-time verification for MLC tracking treatments using time-resolved EPID imaging, which has been published in final form at https://aapm.onlinelibrary.wiley.com/doi/10.1002/mp.14675. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. This article may not be enhanced, enriched or otherwise transformed into a derivative work, without express permission from Wiley or by statutory rights under applicable legislation. Copyright notices must not be removed, obscured or modified. The article must be linked to Wiley’s version of record on Wiley Online Library and any embedding, framing or otherwise making available the article or pages thereof by third parties from platforms, services and websites other than Wiley Online Library must be prohibiteden
usyd.facultySeS faculties schools::Faculty of Medicine and Healthen
usyd.departmentACRF Image X Instituteen
usyd.citation.volume48en
usyd.citation.issue3en
usyd.citation.spage953en
usyd.citation.epage964en
workflow.metadata.onlyNoen


Show simple item record

Associated file/s

Associated collections

Show simple item record

There are no previous versions of the item available.