Magnetic modeling of actively shielded rotating MRI magnets in the presence of environmental steel.
Field | Value | Language |
dc.contributor.author | Whelan, B | |
dc.contributor.author | Leghissa, M | |
dc.contributor.author | Amrei, P | |
dc.contributor.author | Zaitsev, M | |
dc.contributor.author | Heinrich, B | |
dc.contributor.author | Fahrig, R | |
dc.contributor.author | Rohdjess, H | |
dc.date.accessioned | 2021-09-23T22:54:31Z | |
dc.date.available | 2021-09-23T22:54:31Z | |
dc.date.issued | 2021 | en_AU |
dc.identifier.uri | https://hdl.handle.net/2123/26222 | |
dc.description.abstract | Rotating MRI systems could enable novel integrated medical devices such as MRI-Linacs, MRI-xray-angiography systems, and MRI-proton therapy systems. This work aimed to investigate the feasibility of rotating actively shielded superconducting MRI magnets in the presence of environmental steel-in particular, construction steel in the floor of the installation site. Two magnets were investigated: a 1.0 T split bore magnet, and a 1.5 T closed bore magnet. Each magnet was scaled to emulate field strengths of 0.5, 1.0, and 1.5 T. Finite Element Modeling was used to simulate these magnets in the presence of a 3 × 4 m steel plate located 1250 mm or 1400 mm below the isocenter. There are two possible rotation directions: around the longitudinal (z) axis or around the transverse (x) axis. Each model was solved for rotation angles between 0 and 360° in 30° intervals around each of these axes. For each simulation, a 300 mm DSV was extracted and decomposed into spherical harmonics. For the closed-bore magnet, total induced perturbation for the zero degree rotation angle was 223, 432, and 562 μT peak-to-peak (pk-pk) for the 0.5, 1.0, and 1.5 T models respectively (steel at 1250 mm). For the split-bore magnet, the same numbers were 1477, 16747, and 1766 μT. The substantially higher perturbation for the split-bore magnet can be traced to its larger fringe field. For rotation around the z-axis, total perturbation does not change as a function of angle but is exchanged between different harmonics. For rotation around the x-axis, total perturbation is different at each rotation angle. For the closed bore magnet, maximum perturbations occurred for a 90° rotation around the transverse axis. For the split-bore magnet, the opposite was observed, with the same 90° rotation yielding total perturbation lower than the conventional position. In all cases, at least 95% of the total perturbation was composed of 1st and 2nd order harmonics. The presence of environmental steel poses a major challenge to the realization of an actively shielded rotating superconducting MRI system, requiring some novel form of shimming. Possible shimming strategies are discussed at length. | en_AU |
dc.language.iso | en | en_AU |
dc.publisher | IOP Sciences | en_AU |
dc.relation.ispartof | Physics in Medicine & Biology | en_AU |
dc.rights | Copyright All Rights Reserved | en_AU |
dc.subject | magnetic resonance imaging | en_AU |
dc.title | Magnetic modeling of actively shielded rotating MRI magnets in the presence of environmental steel. | en_AU |
dc.type | Article | en_AU |
dc.subject.asrc | 0299 Other Physical Sciences | en_AU |
dc.identifier.doi | 10.1088/1361-6560/abd010 | |
dc.relation.nhmrc | 1163010 | |
usyd.faculty | SeS faculties schools::Faculty of Medicine and Health | en_AU |
usyd.department | ACRF Image X Institute | en_AU |
usyd.citation.volume | 66 | en_AU |
usyd.citation.issue | 4 | en_AU |
usyd.citation.spage | 045004 | en_AU |