dc.description.abstractPurpose: A radiotherapy system with a fixed treatment beam and a rotating patient positioning system could be smaller, more robust and more cost effective compared to conventional rotating gantry systems. However, patient rotation could cause anatomical deformation and compromise treatment delivery. In this work, we demonstrate an image-guided treatment workflow with a fixed beam prototype system that accounts for deformation during rotation to maintain dosimetric accuracy. Methods: The prototype system consists of an Elekta Synergy linac with the therapy beam orientated downward and a custom-built patient rotation system (PRS). A phantom that deforms with rotation was constructed and rotated within the PRS to quantify the performance of two image guidance techniques: motion compensated cone-beam CT (CBCT) for pre-treatment volumetric imaging and kilovoltage infraction monitoring (KIM) for real-time image guidance. The phantom was irradiated with a 3D conformal beam to evaluate the dosimetric accuracy of the workflow. Results: The motion compensated CBCT was used to verify pre-treatment position and the average calculated position was within -0.3 ± 1.1 mm of the phantom's ground truth position at 0°. KIM tracked the position of the target in real-time as the phantom was rotated and the average calculated position was within -0.2 ± 0.8 mm of the phantom's ground truth position. A 3D conformal treatment delivered on the prototype system with image guidance had a 3%/2 mm gamma pass rate of 96.3% compared to 98.6% delivered using a conventional rotating gantry linac. Conclusions: In this work, we have shown that image guidance can be used with fixed-beam treatment systems to measure and account for changes in target position in order to maintain dosimetric coverage during horizontal rotation. This treatment modality could provide a viable treatment option when there insufficient space for a conventional linear accelerator or where the cost is prohibitive.en
dc.language.isoenen
dc.publisherIOP Sciencesen
dc.relation.ispartofPhysics in Medicine & Biologyen
dc.rightsCopyright All Rights Reserveden
dc.subjectimage-guided radiation therapyen
dc.subjectpatient rotationen
dc.titlePre-treatment and real-time image guidance for a fixed-beam radiotherapy system.en
dc.typeArticleen
dc.subject.asrc0299 Other Physical Sciencesen
dc.identifier.doi10.1088/1361-6560/abdc12
dc.relation.arc118450
dc.relation.nhmrc1112096
usyd.facultySeS faculties schools::Faculty of Medicine and Healthen
usyd.departmentACRF Image X Instituteen
usyd.citation.volume66en
usyd.citation.issue6en
usyd.citation.spage064003en
workflow.metadata.onlyNoen


Show simple item record

Associated file/s

Associated collections

Show simple item record

There are no previous versions of the item available.