• New Australian guidelines for the treatment of alcohol problems: an overview of recommendations 

      Haber, Paul S; Riordan, Benjamin C; Winter, Daniel T; Barrett, Liz; Saunders, John; Hides, Leanne; Gullo, Matthew; Manning, Victoria; Day, Carolyn A; Bonomo, Yvonne; Burns, Lucinda; Assan, Robert; Curry, Ken; Mooney-Somers, Julie; Demirkol, Apo; Monds, Lauren; McDonough, Mike; Baillie, Andrew J; Ritter, Alison; Quinn, Catherine; Cunningham, John; Lintzeris, Nicholas; Rombouts, Susan; Savic, Michael; Norman, Amanda; Reid, Sharon; Hutchinson, Delyse; Zheng, Catherine; Iese, Yasmine; Black, Nicola; Draper, Brian; Ridley, Nicole; Gowing, Linda; Stapinski, Lexine; Taye, Belaynew; Lancaster, Kari; Stjepanovic, Daniel; Kay-Lambkin, Frances; Jamshidi, Nazila; Lubman, Dan; Pastor, Adam; White, Natalie; Wilson, Scott; Jaworski, Alison L; Memedovic, Sonja; Logge, Warren; Mills, Katherine; Seear, Kate; Freeburn, Bradley; Lea, Toby; Withall, Adrienne; Marel, Christina; Boffa, John; Roxburgh, Amanda; Purcell-Khodr, Gemma; Doyle, Michael; Conigrave, Kate; Teeson, Maree; Butler, Kerryn; Connor, Jason; Morley, Kirsten C
      Published 2021
      Summary of recommendations and levels of evidence Chapter 2: Screening and assessment for unhealthy alcohol use Screening Screening for unhealthy alcohol use and appropriate interventions should be implemented in ...
      Open Access
      Article
    • Cardiac radioablation for atrial fibrillation: Target motion characterization and treatment delivery considerations. 

      Lydiard, S; Pontre, B; Lowe, B; Ball, H; Sasso, G; Keall, P
      Published 2021
      Purpose: The safe delivery of cardiac radioablation (CR) for atrial fibrillation (AF) is challenged by multi-direction target motion, cardiac rate variability, target proximity to critical structures, and the importance ...
      Open Access
      Article
    • Magnetic modeling of actively shielded rotating MRI magnets in the presence of environmental steel. 

      Whelan, B; Leghissa, M; Amrei, P; Zaitsev, M; Heinrich, B; Fahrig, R; Rohdjess, H
      Published 2021
      Rotating MRI systems could enable novel integrated medical devices such as MRI-Linacs, MRI-xray-angiography systems, and MRI-proton therapy systems. This work aimed to investigate the feasibility of rotating actively ...
      Open Access
      Article
    • Pre-treatment and real-time image guidance for a fixed-beam radiotherapy system. 

      Liu, P; Gardner, M; Heng, SM; Shieh, C-C; Nguyen, DT; Debrot, E; O'Brien, R; Downes, S; Jackson, M; Keall, P
      Published 2021
      Purpose: A radiotherapy system with a fixed treatment beam and a rotating patient positioning system could be smaller, more robust and more cost effective compared to conventional rotating gantry systems. However, patient ...
      Open Access
      Article
    • Pelvic organ motion and dosimetric implications during horizontal patient rotation for prostate radiation therapy. 

      Buckley, J; Dowling, J; Sidhom, M; Liney, G; Rai, R; Metcalfe, p; Holloway, L; Keall, P
      Published 2021
      Purpose: Gantry-free radiation therapy systems utilizing patient rotation would be simpler and more cost effective than the conventional gantry-based systems. Such a system could enable the expansion of radiation therapy ...
      Open Access