Show simple item record

FieldValueLanguage
dc.contributor.authorLeung, Sharon Shui Yee
dc.contributor.authorChiow, Adam Chong Ming
dc.contributor.authorKwok, Philip Chi Lip
dc.contributor.authorUkkonen, Ari
dc.contributor.authorChan, Hak-Kim
dc.date.accessioned2020-09-28
dc.date.available2020-09-28
dc.date.issued2017-01-01en_AU
dc.identifier.urihttps://hdl.handle.net/2123/23486
dc.description.abstractAerosols emitted from metered dose inhalers (MDIs) are generally electrically charged and bipolar in nature. Although a spacer can effectively dampen the charge magnitude of aerosols, the electrostatic interactions between the positively and negatively charged particles and the spacer have not yet been characterized separately. The Bipolar Charge Analyzer (BOLAR) was employed to investigate interactions between the spacer and the charged aerosols. Three individual actuations of Tilade® MDI were introduced without a spacer and through an antistatic AeroChamber Plus® Z Stat®, an uncoated and a detergent-coated AeroChamber Plus® spacer into the BOLAR at 60 L/min. Charge and mass profiles were determined. The surface potential of spacers followed the order of uncoated > detergent-coated > antistatic spacer. The spacers had minimal impact on the positively charged particles but the charge magnitude of the negatively charged particles was in the opposite order as the spacer surface potential. The charge-to-mass ratio of particles had little alteration for all measurements. Negatively charged particles had a higher tendency to deposit on the spacer walls, possibly due to their higher abundance in the confined spacer volume. The bipolar data may prove useful for designing better MDIs and spacers and modelling lung deposition of charged aerosol particles.en_AU
dc.language.isoenen_AU
dc.publisherElsevieren_AU
dc.relation.ispartofJournal of Pharmaceutical Sciencesen_AU
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivatives 4.0en_AU
dc.subjectaerosol
dc.subjectdispersion
dc.subjectpMDI
dc.subjectpressurized metered dose inhaler
dc.subjectpulmonary
dc.subjectstatic charge
dc.titleEffect of Spacers on the Bipolar Electrostatic Charge Properties of Metered Dose Inhaler Aerosols-A Case Study With Tilade ®en_AU
dc.typeArticleen_AU
dc.subject.asrc1115 Pharmacology and Pharmaceutical Sciencesen_AU
dc.identifier.doi10.1016/j.xphs.2017.02.014
dc.relation.arcDP160102577
usyd.facultySeS faculties schools::Faculty of Medicine and Health::Sydney Pharmacy Schoolen_AU
usyd.citation.volume106en_AU
usyd.citation.issue6en_AU
usyd.citation.spage1553en_AU
usyd.citation.epage1559en_AU
workflow.metadata.onlyNoen_AU


Show simple item record

Associated file/s

Associated collections

Show simple item record

There are no previous versions of the item available.