Show simple item record

FieldValueLanguage
dc.contributor.authorYastrebov, Konstantin
dc.contributor.authorBrunel, Laurencie
dc.contributor.authorPaterson, Hugh
dc.contributor.authorWilliams, Zoe
dc.contributor.authorBannon, Paul
dc.date.accessioned2020-09-02
dc.date.available2020-09-02
dc.date.issued2020-01-01en_AU
dc.identifier.urihttps://hdl.handle.net/2123/23237
dc.description.abstractBackground Three-dimensional intracardiac echocardiography (3D ICE) with wide azimuthal elevation is a novel technique performed for assessment of cardiac anatomy and guidance of intracardiac procedures. It offers, being able to provide unique views with good spatial and temporal resolution. Complications arising from this highly invasive procedure and the value of 3D ICE in the detection and diagnosis of acute cardiovascular pathology are not comprehensively described. This case illustrates a previously unreported iatrogenic complication of clot displacement from the intra-vascular sheath upon insertion of a 3D ICE catheter and the value of 3D ICE in immediate diagnosis of clot in transit through the heart with pulmonary embolism. Case presentation We conducted a translational study of three-dimensional intracardiac echocardiography3D ICE with wide azimuthal elevation to guide implantation of a left ventricular assist device (Impella CP®) in eight adult sheep. A large-bore 14 Fr central venous sheath was used to enable right atrial and right ventricular access for the intracardiac catheter. Insertion of the 3D ICE catheter was accompanied by a sudden severe cardiorespiratory deterioration in one animal. 3D ICE revealed a large highly mobile mass within the right heart chambers, determined to be a clot-in-transit. The diagnosis of pulmonary clot embolism resulting from the retrograde blood entry into the large-bore sheath introducer, rapid clot formation and consequent displacement into venous circulation by the ICE catheter was made. The sheep survived this life-threatening event following institution of cardiovascular support allowing completion of the primary research protocol. Conclusion This report serves as a serious warning to the researchers and clinicians utilizing long large-bore sheath introducers for 3D ICE and illustrates the value of 3D ICE in detecting clot-in-transit within right heart chambers.en_AU
dc.language.isoenen_AU
dc.publisherBMCen_AU
dc.relation.ispartofCardiovascular Ultrasounden_AU
dc.rightsCreative Commons Attribution-NonCommercial-ShareAlike 4.0en_AU
dc.subjectthree-dimensional intracardiac echocardiographyen_AU
dc.subjectpulmonary embolismen_AU
dc.titleThree-dimensional intracardiac echocardiography and pulmonary embolismen_AU
dc.typeArticleen_AU
dc.subject.asrc11 Medical and Health Sciencesen_AU
dc.identifier.doi10.1186/s12947-020-00220-3
usyd.facultySeS faculties schools::Faculty of Medicine and Healthen_AU
usyd.departmentSydney Core Research Facilityen_AU
usyd.citation.volume16en_AU
usyd.citation.spage36en_AU
workflow.metadata.onlyNoen_AU


Show simple item record

Associated file/s

Associated collections

Show simple item record

There are no previous versions of the item available.