Show simple item record

FieldValueLanguage
dc.contributor.authorLee, D
dc.contributor.authorKim, S
dc.contributor.authorPalta, J
dc.contributor.authorLewis, B
dc.contributor.authorKeall, P
dc.contributor.authorKim, T
dc.date.accessioned2020-01-08
dc.date.available2020-01-08
dc.date.issued2019-06-01
dc.identifier.citationJ Med Imaging Radiat Oncol. 2019 Jun;63(3):360-369en
dc.identifier.urihttps://hdl.handle.net/2123/21622
dc.description.abstractINTRODUCTION: 4D-MRI, compared to 4D-CT, provides better soft-tissue contrast for target delineation. However, motion artefacts are often observed due to residual breathing variations. This study is to present a retrospective 4D-MRI reconstruction method based on 2D diaphragm profiles to improve the quality of 4D-MR images in the presence of significant breathing variations. METHODS: The proposed 4D-MRI reconstruction method utilized diaphragm profiles (2D cine images on a single sagittal plan at the peak diaphragm) in conjunction with 4D-MR scans (2D-cine images on multiple pre-determined coronal planes along the anterior-posterior direction over a volume of interest). The diaphragm profile images were exploited to sort the 4D-MR scans by matching respiratory amplitude of diaphragm on the 4D-MR scans to the diaphragm profiles. To evaluate reconstructed 4D-MR images (ten 3D-MR images), sagittal images on ten 3D-MR images under free breathing (FB) and respiratory guidance (GB) were compared with diaphragm profile images (reference) from 13 healthy volunteers. RESULTS: Forty-four 4D-MR scan datasets were successfully reconstructed without distinct respiratory-related motion artefacts even with the presence of breathing variation. The differences in diaphragm profiles between the reference and corresponding reconstructed images in the mean of root mean square were similar between FB (3.5 mm) and GB (3.0 mm), confirming that the 4D-MRI reconstruction method was effective even with significant breathing variation. CONCLUSIONS: The diaphragm profiles were utilized to reconstruct 4D-MR images with spatial reliability and a fixed scan time under FB and GB. Our method can provide reliable 4D information of thoracic and abdominal regions for MRI-guided radiotherapy.en
dc.language.isoen_USen
dc.publisherWileyen
dc.relationNHMRC 1112096en
dc.rightsOtheren
dc.subjectmotion managementen
dc.titleA retrospective 4D-MRI based on 2D diaphragm profiles for lung cancer patients.en
dc.typeArticleen
dc.subject.asrc029903en
dc.identifier.doi10.1111/1754-9485.12877
dc.type.pubtypeAuthor accepted manuscripten
dc.rights.other"This is the peer reviewed version of the following article: Lee, D., Kim, S., Palta, J., Lewis, B., Keall, P. and Kim, T. (2019), A retrospective 4D‐MRI based on 2D diaphragm profiles for lung cancer patients. J Med Imaging Radiat Oncol, 63: 360-369., which has been published in final form at https://doi.org/10.1111/1754-9485.12877 . This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions."en
usyd.facultyFaculty of Medicine and Health, Sydney Medical Schoolen


Show simple item record