dc.description.abstractBACKGROUND AND PURPOSE: To perform a quantitative analysis of the accuracy and precision of Kilovoltage Intrafraction Monitoring (KIM) six degree-of-freedom (6DoF) prostate motion measurements during treatments. MATERIAL AND METHODS: Real-time 6DoF prostate motion was acquired using KIM for 14 prostate cancer patients (377 fractions). KIM outputs the 6DoF prostate motion, combining 3D translation and 3D rotational motion information relative to its planning position. The corresponding groundtruth target motion was obtained post-treatment based on kV/MV triangulation. The accuracy and precision of the 6DoF KIM motion estimates were calculated as the mean and standard deviation differences compared with the ground-truth. RESULTS: The accuracy ± precision of real-time 6DoF KIM-measured prostate motion were 0.2 ± 1.3° for rotations and 0.1 ± 0.5 mm for translations, respectively. The magnitude of KIM-measured motion was well-correlated with the magnitude of ground-truth motion resulting in Pearson correlation coefficients of  ≥0.88 in all DoF. CONCLUSIONS: The results demonstrate that KIM is capable of providing the real-time 6DoF prostate target motion during patient treatments with an accuracy ± precision of within 0.2 ± 1.3° and 0.1 ± 0.5 mm for rotation and translation, respectively. As KIM only requires a single X-ray imager, which is available on most modern cancer radiotherapy devices, there is potential for widespread adoption of this technology.en_AU
dc.publisherElsevieren_AU
dc.relationNHMRC 1112096en_AU
dc.subjectImage-guided radiotherapyen_AU
dc.subjectmotion managementen_AU
dc.titleThe accuracy and precision of Kilovoltage Intrafraction Monitoring (KIM) six degree-of-freedom prostate motion measurements during patient treatments.en_AU
dc.typeArticleen_AU
dc.subject.asrcFoR::029903 - Medical Physicsen_AU
dc.identifier.doi10.1016/j.radonc.2017.10.030
dc.type.pubtypePost-printen_AU


Show simple item record

Associated file/s

Associated collections

Show simple item record

There are no previous versions of the item available.