Show simple item record

FieldValueLanguage
dc.contributor.authorLee, D
dc.contributor.authorGreer, PB
dc.contributor.authorLudbrook, J
dc.contributor.authorArm, J
dc.contributor.authorHunter, P
dc.contributor.authorPollock, S
dc.contributor.authorMakhija, K
dc.contributor.authorO'Brien, RT
dc.contributor.authorKim, T
dc.contributor.authorKeall, P
dc.date.accessioned2018-07-09
dc.date.available2018-07-09
dc.date.issued2016-03-01
dc.identifier.citationInt J Radiat Oncol Biol Phys. 2016 Mar 1;94(3):628-36.en_AU
dc.identifier.urihttp://hdl.handle.net/2123/18542
dc.description.abstractPURPOSE: To assess the impact of an audiovisual (AV) biofeedback on intra- and interfraction tumor motion for lung cancer patients. METHODS AND MATERIALS: Lung tumor motion was investigated in 9 lung cancer patients who underwent a breathing training session with AV biofeedback before 2 3T magnetic resonance imaging (MRI) sessions. The breathing training session was performed to allow patients to become familiar with AV biofeedback, which uses a guiding wave customized for each patient according to a reference breathing pattern. In the first MRI session (pretreatment), 2-dimensional cine-MR images with (1) free breathing (FB) and (2) AV biofeedback were obtained, and the second MRI session was repeated within 3-6 weeks (mid-treatment). Lung tumors were directly measured from cine-MR images using an auto-segmentation technique; the centroid and outlier motions of the lung tumors were measured from the segmented tumors. Free breathing and AV biofeedback were compared using several metrics: intra- and interfraction tumor motion consistency in displacement and period, and the outlier motion ratio. RESULTS: Compared with FB, AV biofeedback improved intrafraction tumor motion consistency by 34% in displacement (P=.019) and by 73% in period (P<.001). Compared with FB, AV biofeedback improved interfraction tumor motion consistency by 42% in displacement (P<.046) and by 74% in period (P=.005). Compared with FB, AV biofeedback reduced the outlier motion ratio by 21% (P<.001). CONCLUSIONS: These results demonstrated that AV biofeedback significantly improved intra- and interfraction lung tumor motion consistency for lung cancer patients. These results demonstrate that AV biofeedback can facilitate consistent tumor motion, which is advantageous toward achieving more accurate medical imaging and radiation therapy procedures.en_AU
dc.publisherElsevieren_AU
dc.relationNHMRC 633000; NHMRC 1112096en_AU
dc.rightsThe final authenticated version is available online at: 10.1016/j.ijrobp.2015.11.017. Int J Radiat Oncol Biol Phys. 2016 Mar 1;94(3):628-36.with CC-BY-NC-ND license
dc.subjectmotion managementen_AU
dc.subjectbreathing guidanceen_AU
dc.titleAudiovisual Biofeedback Improves Cine-Magnetic Resonance Imaging Measured Lung Tumor Motion Consistency.en_AU
dc.typeArticleen_AU
dc.subject.asrc029903en_AU
dc.identifier.doi10.1016/j.ijrobp.2015.11.017
dc.type.pubtypePre-printen_AU


Show simple item record

Associated file/s

Associated collections

Show simple item record

There are no previous versions of the item available.