dc.description.abstractRespiratory triggered four dimensional cone-beam computed tomography (RT 4D CBCT) is a novel technique that uses a patient's respiratory signal to drive the image acquisition with the goal of imaging dose reduction without degrading image quality. This work investigates image quality and dose using patient-measured respiratory signals for RT 4D CBCT simulations. Studies were performed that simulate a 4D CBCT image acquisition using both the novel RT 4D CBCT technique and a conventional 4D CBCT technique. A set containing 111 free breathing lung cancer patient respiratory signal files was used to create 111 pairs of RT 4D CBCT and conventional 4D CBCT image sets from realistic simulations of a 4D CBCT system using a Rando phantom and the digital phantom, XCAT. Each of these image sets were compared to a ground truth dataset from which a mean absolute pixel difference (MAPD) metric was calculated to quantify the degradation of image quality. The number of projections used in each simulation was counted and was assumed as a surrogate for imaging dose. Based on 111 breathing traces, when comparing RT 4D CBCT with conventional 4D CBCT, the average image quality was reduced by 7.6% (Rando study) and 11.1% (XCAT study). However, the average imaging dose reduction was 53% based on needing fewer projections (617 on average) than conventional 4D CBCT (1320 projections). The simulation studies have demonstrated that the RT 4D CBCT method can potentially offer a 53% saving in imaging dose on average compared to conventional 4D CBCT in simulation studies using a wide range of patient-measured breathing traces with a minimal impact on image quality.en
dc.publisherIOPscienceen
dc.relationNHMRC 633000; NHMRC 1034060en
dc.rightsOther
dc.subjectmotion managementen
dc.subjectrepiratory-gated 4D CBCTen
dc.titleQuantifying the image quality and dose reduction of respiratory triggered 4D cone-beam computed tomography with patient-measured breathing.en
dc.typeArticleen
dc.subject.asrc029903en
dc.identifier.doi10.1088/0031-9155/60/24/9493
dc.type.pubtypePreprinten
usyd.facultyFaculty of Medicine and Health, Sydney Medical Schoolen


Show simple item record

Associated file/s

Associated collections

Show simple item record

There are no previous versions of the item available.