Show simple item record

FieldValueLanguage
dc.contributor.authorCrawley, Adam
dc.date.accessioned2026-02-19T03:49:48Z
dc.date.available2026-02-19T03:49:48Z
dc.date.issued2007en
dc.identifier.otherMMSID: 991025859429705106en
dc.identifier.urihttps://hdl.handle.net/2123/34870
dc.description.abstractThe complementary application of Gas Chromatography-Mass Spectrometry (GC-MS) and Gas Chromatography-Combustion-Isotope Ratio Mass Spectrometry (GC-C-IRMS) were used in this study to provide compound specific detection of endogenous steroid misuse for improved anti-doping analysis. Administrations of synthetically derived dehydroepiandrosterone, androstenedione, 4-androstenediol, 5-androstenediol and testosterone were specifically confirmed on the basis of abnonnal urinary excretions and low C content of their respective diagnostic markers; 3oc,5-cyclo-5a-androstane-6p-ol- 17-one, 40H-androstenedione, androst-2,4-diene-17-one/androst-3,5-diene-17-one, etiocholanolone sulfoconjugate and testosterone. A comprehensive reference interval study established the natural variation, predominantly 1 o from diet, observed for 8 C values in an elite athlete population (n = 1262) representing n 13 countries. The minimum 8 C values recorded for the terminal androgen metabolites; androsterone and etiocholanolone were -25.3%o and -25.8%o, respectively. A maximum of i 3.8%o was observed for the associated A8 C value that incorporated 1 lketoetiocholanolone as the endogenous reference compound. Parametric statistics were applied to these data sets to propose high confidence (mean ± 3 standard deviations) 8 C and A813C limits of -27.0%o and 4.0%o to define endogenous steroid abuse. The use of pregnanediol as the endogenous reference compound provided a lower A8I3C limit of 3.0%o. The combinatorial approach to GC-MS and GC-C-IRMS data analysis was used to investigate the potential for metabonomics - the study of a discrete metabolite set - to improve anti-doping science. This methodology allowed the simple interpretation of all relevant information concerning an individual’s metabolism in order to make an informed decision with respect to a doping violation.en
dc.language.isoenen
dc.subjectDrug testingen
dc.subjectDoping in sportsen
dc.titleCompound specific detection of endogenous steroid abuse in sport: A metabonomic perspectiveen
dc.typeThesis
dc.type.thesisDoctor of Philosophyen
dc.rights.otherThe author retains copyright of this thesis. It may only be used for the purposes of research and study. It must not be used for any other purposes and may not be transmitted or shared with others without prior permission.en
usyd.facultyFaculty of Science, School of Chemistryen
usyd.degreeDoctor of Philosophy Ph.D.en
usyd.awardinginstThe University of Sydneyen
usyd.advisorGeorge, Adrian V
usyd.advisorKazlaushas, Rymantas
usyd.advisorTrout, Graham J
usyd.description.notesThis thesis has been made available through exception 200AB to the Copyright Act.


Show simple item record

Associated file/s

Associated collections

Show simple item record

There are no previous versions of the item available.