Show simple item record

FieldValueLanguage
dc.contributor.authorGoodwin, Andrew James
dc.date.accessioned2023-08-24T01:10:27Z
dc.date.available2023-08-24T01:10:27Z
dc.date.issued2023en
dc.identifier.urihttps://hdl.handle.net/2123/31599
dc.description.abstractIntensive care medicine is a resource intense environment in which technical and clinical decision making relies on rapidly assimilating a huge amount of categorical and timeseries physiologic data. These signals are being presented at variable frequencies and of variable quality. Intensive care clinicians rely on high frequency measurements of the patient's physiologic state to assess critical illness and the response to therapies. Physiological waveforms have the potential to reveal details about the patient state in very fine resolution, and can assist, augment, or even automate decision making in intensive care. However, these high frequency time-series physiologic signals pose many challenges for modelling. These signals contain noise, artefacts, and systematic timing errors, all of which can impact the quality and accuracy of models being developed and the reproducibility of results. In this context, the central theme of this thesis is to model the process of data collection in an intensive care environment from a statistical, metrological, and biosignals engineering perspective with the aim of identifying, quantifying, and, where possible, correcting errors introduced by the data collection systems. Three different aspects of physiological measurement were explored in detail, namely measurement of blood oxygenation, measurement of blood pressure, and measurement of time. A literature review of sources of errors and uncertainty in timing systems used in intensive care units was undertaken. A signal alignment algorithm was developed and applied to approximately 34,000 patient-hours of simultaneously collected electroencephalography and physiological waveforms collected at the bedside using two different medical devices.en
dc.language.isoenen
dc.rightsCopyright All Rights Reserveden
dc.subjectmetrologyen
dc.subjectsynchronisationen
dc.subjecttimeen
dc.subjectICUen
dc.subjectphysiologyen
dc.subjectEEGen
dc.titleHigh Frequency Physiological Data Quality Modelling in the Intensive Care Uniten
dc.typeThesis
dc.type.thesisDoctor of Philosophyen
dc.rights.otherThe author retains copyright of this thesis. It may only be used for the purposes of research and study. It must not be used for any other purposes and may not be transmitted or shared with others without prior permission.en
usyd.facultySeS faculties schools::Faculty of Engineering::School of Biomedical Engineeringen
usyd.degreeDoctor of Philosophy Ph.D.en
usyd.awardinginstThe University of Sydneyen
usyd.advisorMcEwan, Alistairen


Show simple item record

Associated file/s

Associated collections

Show simple item record

There are no previous versions of the item available.