Show simple item record

FieldValueLanguage
dc.contributor.authorInness, Philip Ralph Patton
dc.date.accessioned2022-02-23T03:53:18Z
dc.date.available2022-02-23T03:53:18Z
dc.date.issued2021en_AU
dc.identifier.urihttps://hdl.handle.net/2123/27503
dc.description.abstractReliable microvascular identification and quantitative vascular assessment via Micro-CT collection of intraosseous measurements has not been reported in dogs. The aim of this study was to identify the ideal preparation (Criteria: perfusability, radiodensity and homogeneity) for quantitative assessment of canine intraosseous microvasculature. Materials/Methods: Cadaveric specimens were perfused initially with resin preparations [Resin Study: Barium+Resin (BS+R), Barium, Acetone+Resin (BSA+R), Barium Slurry+Resin (BSS+R), and Barium Slurry, Acetone+Resin (BSSA+R)]. BSS+R was then compared with Barium+Saline (BSS) and Barium+Gelatine (BSG) [Comparative Study] using micro-CT via mean radiodensity and Coefficient of Variation (n=20) [vessels >1mm2, 0.3mm2-1mm2 and <0.2mm2] and intraosseous vessel diameter (<200µm) and distribution within the femur, tibia and patella (n=12). Results: Resin Study: BSS+R identified a greater proportion and number of small intraosseous vessels <100µm with a similar mean radiodensity and homogeneity across all vessel sizes. All test preparations were superior to the control (BS+R). The addition of saline, acetone or both improved vessel perfusion. The homogeneity of all preparations was poor with significant variation. Comparative Study: BSS and BSG exhibited larger mean radiodensity compared with BSS+R (P<0.001) at all vessel sizes. BSG produced the most homogenous preparation. All preparations identified vessels to two scan voxels in diameter. BSS exhibiting the smallest mean vessel diameter, greatest proportion (P<0.001) and number of different vessel diameters <100µm. Conclusions: BSS is the most appropriate suspension for analysis of canine intraosseous microvasculature resulting in a significantly more accurate and detailed quantitative microvascular analysis. Resin preparations performed poorly within all characteristics and were inferior to both BSS and BSG. No resin preparation produced a homogeneous suspension in any vessel size.en_AU
dc.language.isoenen_AU
dc.subjectMicro-CTen_AU
dc.subjectmicrovascularen_AU
dc.subjectintraosseousen_AU
dc.subjectcanineen_AU
dc.subjectbariumen_AU
dc.subjectangiogramen_AU
dc.titleAssessment of different contrast preparations for micro-computed tomographic microangiographic assessment of canine cadaveric hindlimbsen_AU
dc.typeThesis
dc.type.thesisMasters by Researchen_AU
dc.rights.otherThe author retains copyright of this thesis. It may only be used for the purposes of research and study. It must not be used for any other purposes and may not be transmitted or shared with others without prior permission.en_AU
usyd.facultySeS faculties schools::Faculty of Science::Sydney Institute of Veterinary Scienceen_AU
usyd.degreeMaster of Veterinary Clinical Studies M.Vet.Clin.Stud.en_AU
usyd.awardinginstThe University of Sydneyen_AU
usyd.advisorJohnson, Kenneth