Show simple item record

FieldValueLanguage
dc.contributor.authorAspland, A.en_AU
dc.contributor.authorChew, C.en_AU
dc.contributor.authorDouagi, I.en_AU
dc.contributor.authorGalland, T.en_AU
dc.contributor.authorMarvin, J.en_AU
dc.contributor.authorMonts, J.en_AU
dc.contributor.authorNance, D.en_AU
dc.contributor.authorSmith, A.L.en_AU
dc.contributor.authorSolga, M.en_AU
dc.date.accessioned2021-06-02T04:55:25Z
dc.date.available2021-06-02T04:55:25Z
dc.date.issued2021
dc.identifier.urihttps://hdl.handle.net/2123/25319
dc.description.abstractThe COVID-19 pandemic has brought biosafety to the forefront of many life sciences. The outbreak has compelled research institutions to re-evaluate biosafety practices and potential at-risk areas within research laboratories and more specifically within Shared Resource Laboratories (SRLs). In flow cytometry facilities, biological safety assessment encompasses known hazards based on the biological sample and associated risk group, as well as potential or unknown hazards, such as aerosol generation and instrument “failure modes.” Cell sorting procedures undergo clearly defined biological safety assessments and adhere to well-established biosafety guidelines that help to protect SRL staff and users against aerosol exposure. Conversely, benchtop analyzers are considered low risk due to their low sample pressure and enclosed fluidic systems, although there is little empirical evidence to support this assumption of low risk. To investigate this, we evaluated several regions on analyzers using the Cyclex-d microsphere assay, a recently established method for cell sorter aerosol containment testing. We found that aerosol and/or droplet hazards were detected on all benchtop analyzers predominantly during operation in “failure modes.” These results indicate that benchtop analytical cytometers present a more complicated set of risks than are commonly appreciated.en_AU
dc.language.isoenen_AU
dc.subjectCOVID-19en_AU
dc.subjectCoronavirusen_AU
dc.titleRisk awareness during operation of analytical flow cytometers and implications throughout the COVID-19 pandemicen_AU
dc.typeArticleen_AU
dc.identifier.doi10.1002/cyto.a.24282
dc.relation.otherNational Institutes of Health, NIH National Institute of Allergy and Infectious Diseases, NIAID University of Utahen_AU


Show simple item record

Associated file/s

There are no files associated with this item.

Associated collections

Show simple item record

There are no previous versions of the item available.