Show simple item record

FieldValueLanguage
dc.contributor.authorHegi-Johnson, F
dc.contributor.authorde Ruysscher, D
dc.contributor.authorKeall, P
dc.contributor.authorHendriks, L
dc.contributor.authorVinogradskiy, Y
dc.contributor.authorYamamoto, T
dc.contributor.authorTahir, B
dc.contributor.authorKipritidis, J
dc.date.accessioned2020-07-11
dc.date.available2020-07-11
dc.date.issued2019-01-01en_AU
dc.identifier.urihttps://hdl.handle.net/2123/22850
dc.description.abstractComputed Tomography Ventilation Imaging (CTVI) is an experimental imaging modality that derives regional lung function information from non-contrast respiratory-correlated CT datasets. Despite CTVI being extensively studied in cross-modality imaging comparisons, there is a lack of consensus on the state of its clinical validation in humans. This systematic review evaluates the CTVI clinical validation studies to date, highlights their common strengths and weaknesses and makes recommendations. We performed a PUBMED and EMBASE search of all English language papers on CTVI between 2000 and 2018. The results of these searches were filtered in accordance to a set of eligibility criteria and analysed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) Guidelines. One hundred and forty-four records were identified, and 66 full text records were reviewed. After detailed assessment, twenty-three full text papers met the selection criteria and were included in the final review. This included thirteen prospective studies, with 579 human subjects. Studies used diverse methodologies, with a large amount of heterogeneity between different studies in terms of the reference ventilation imaging modality (e.g. nuclear medicine, hyperpolarised gas MRI), imaging parameters, DIR algorithm(s) used, and ventilation metric(s) applied. The most common ventilation metrics used deformable image registration to evaluate the exhale-to-inhale motion field Jacobian determinant (DIR-Jac) or changes in air volume content based on Hounsfield Units (DIR-HU). The strength of correlation between CTVI and the reference ventilation imaging modalities was moderate to strong when evaluated at the lobar or global level, with the average ± S.D. (number of studies) linear regression correlation coefficients were 0.73 ± 0.25 (n = 6) and 0.86 ± 0.11 (n = 12) for DIR-Jac and DIR-HU respectively, and the SPC were 0.45 ± 0.31 (n = 6) and 0.41 ± 0.11 (n = 5) for DIR-Jac and DIR-HU respectively. We concluded that it is difficult to make a broad statement about the validity of CTVI due to the diverse methods used in the validation literature. Typically, CTVI appears to show reasonable cross-modality correlations at the lobar/whole lung level but poor correlations at the voxel level. Since CTVI is seeing new implementations in prospective trials, it is clear that refinement and standardization of the clinical validation methodologies are required. CTVI appears to be of relevance in radiotherapy planning, particularly in patients whose main pulmonary impairment is not a gas exchange problem but alternative imaging approaches may need to be considered in patients with other pulmonary diseases (i.e. restrictive or gas exchange problems).en_AU
dc.language.isoenen_AU
dc.publisherElsevieren_AU
dc.relation.ispartofRadiotherapy & Oncologyen_AU
dc.rightsCopyright All Rights Reserveden_AU
dc.subjectlung canceren_AU
dc.subjectcomputed tomographyen_AU
dc.titleImaging of regional ventilation: Is CT ventilation imaging the answer? A systematic review of the validation data.en_AU
dc.typeArticleen_AU
dc.subject.asrc0299 Other Physical Sciencesen_AU
dc.identifier.doi10.1016/j.radonc.2019.03.010
dc.relation.nhmrc1112096
dc.rights.otherCC BY-NC-NDen_AU
usyd.facultySeS faculties schools::Faculty of Medicine and Health::Central Clinical Schoolen_AU
usyd.departmentACRF Image X Instituteen_AU
usyd.citation.volume137en_AU
usyd.citation.spage175en_AU
usyd.citation.epage185en_AU
workflow.metadata.onlyNoen_AU


Show simple item record

Associated file/s

Associated collections

Show simple item record

There are no previous versions of the item available.