• Imaging performance of a dedicated radiation transparent RF coil on a 1.0 Tesla inline MRI-linac. 

      Liney, GP; Dong, B; Weber, E; Rai, R; Destruel, A; Garcia-Alvarez, R; Manton, DJ; Jelen, U; Zhang, K; Barton, M; Keall, P; Crozier, S
      Published 2018-06-01
      This work describes the first imaging studies on a 1.0 Tesla inline MRI-Linac using a dedicated transmit/receive RF body coil that has been designed to be completely radio transparent and provide optimum imaging performance ...
      Open Access
      Article
    • Technical Note: Experimental Characterization of the Dose Deposition in Parallel MRI-linacs at Various Magnetic Field Strengths 

      Begg, J; Alnaghy, S; Causer, T; Alharthi, T; George, A; Glaubes, L; Dong, B; Goozee, G; Keall, P; Jelen, U; Liney, G; Holloway, L
      Published 2019-01-01
      Purpose: Dose deposition measurements for parallel MRI-linacs have previously only shown comparisons between 0 T and a single available magnetic field. The Australian MRI-Linac consists of a magnet coupled with a dual ...
      Open Access
      Article
    • Technical Note: Experimental results from a prototype high-field inline MRI-linac. 

      Liney, GP; Dong, B; Begg, J; Vial, P; Zhang, K; Lee, F; Walker, A; Rai, R; Causer, T; Alnaghy, SJ; Oborn, BM; Holloway, L; Metcalfe, P; Barton, M; Crozier, S; Keall, P
      Published 2016-09-01
      PURPOSE: The pursuit of real-time image guided radiotherapy using optimal tissue contrast has seen the development of several hybrid magnetic resonance imaging (MRI)-treatment systems, high field and low field, and inline ...
      Open Access
      Article
    • Technical Note: The first live treatment on a 1.0 Tesla inline MRI-linac. 

      Liney, G; Jelen, U; Byrne, H; Dong, B; Roberts, TL; Kuncic, Z; Keall, P
      Published 2019-01-01
      Purpose: This work describes the first live imaging and radiation delivery performed on a prototype 1.0 T inline MRI-Linac system in a rat brain tumor model, which was conducted on 29 January 2019. Methods: A human scale ...
      Open Access
      Article
    • Towards real-time 4D radiation dosimetry on an MRI-Linac 

      De Deene, Y; Wheatley, M; Dong, B; Roberts, N; Jelen, U; Waddington, D; Liney, G
      Published 2020
      4D radiation dosimetry using a highly radiation-sensitive polymer gel dosimeter with real-time quantitative magnetic resonance imaging (MRI) readout is presented as a technique to acquire the accumulated radiation dose ...
      Open Access
      Article