*****************************************************DATA CREATORS***************************************************** CREATORS: Dr Mark Gardner CONTRIBUTORS: Dr Youssef Ben Bouchta, Daniel Truant, Dr Adam Mylonas, Dr Jonathan Sykes, A/Prof Purnima Sundaresan, Prof Paul Keall CONTACT: mark.gardner@sydney.edu.au ********************************************************DATA FILES********************************************************* FOLDER STRUCTURES: |-Patient Planning CTs #CT images used for planning | |-PAT01 #Patient Name | | |-.*dcm #Dicom Files | |-... |-Patient Structure Sets #Contoured Structures used for planning | |-PAT01 #Patient Name | | |-.*dcm #Dicom Files | |-... |-Patient Dose Files #Planned treatment dose volumes | |-PAT01 #Patient Name | | |-.*dcm #Dicom Files | |-... |-Patient Plans #Patient planning information | |-PAT01 #Patient Name | | |-.*dcm #Dicom Files | |-... |-Patient CBCTs #Cone beam CT images | |-PAT01 #Patient Name | | |-Fx01 #Treatment/Fraction number | | | |-.*dcm #Dicom Files |-Patient Registration Files #Couch shifts used to align patients prior to treatment | |-PAT01 #Patient Name | | |-Fx01 #Treatment/Fraction number | | | |-.*dcm #Dicom Files |-PAT01kVImages #kV images (projections) used to create CBCT images for Patient 01 | |-Fx01 #Treatment/Fraction number | | |-Scan.xml #Scan geomtetry/information file | | |-.*xim #Projection Files |-PAT02kVImages | |-... ... |-Pat32kVImages | |-... *****************************************************DATA SOURCES***************************************************** WHERE: Blacktown Cancer & Haematology Centre, Blacktown Hospital, Sydney, New South Wales, Australia WHEN: 2022-2023 ****************************************************DATA DEFINITIONS**************************************************** VARIABLES: See Scan.xml files for CBCT projection geometry information, although individual kV projection angle data can be extracted from xim headers. Isocentre information can be extracted from patient planning data. **********************************************TECHNICAL REQUIREMENTS********************************************** HARDWARE: The planning CT volume was acquired using a Siemens SomatomDefinition AS 64. CBCT and kV images were acquired (and patients were treated) using a Varian TrueBeam. Planning data was generated using Eclipse (Varian). SOFTWARE: For non-clinical use of this data, the data can be veiwed using 3D Slicer (https://www.slicer.org/) FILE FORMATS: Data is in dicom format, except for the kV images which are in xim format. **********************************************Other notes********************************************** There is no patient 08 or patient 27. Patients 11 and 12 had a replan. The additional CT, dose and plan etc for the replan were treated as an additional patient (11_2 and 12_2).